SPECIFICATIONS
| Operating Temperature Range | -40°F to +150°F |
| Input Power Type | AC or DC |
| Input Power if AC | 120VAC @ 5W |
| Input Power if DC | 12VDC @ 200mA |
| Maximum Wind Speed | 120MPH |
| Humidity Range | 5-99% |
| Temperature Range (air) | -40°F to 150°F |
| Temperature Range (water) | Liquid to 120°F |
| Accuracy calibrated (uncalibrated): | |
| --- Temperature (°F) | +/- 1°F (+/- 2.5°F) |
| --- Wind Speed (MPH) | +/- 2MPH (+/- 4MPH) |
| --- Relative Humidity (%) | +/- 2% (+/3.5%) |
| --- Barometric Pressure (InHg) | +/- 0.01 (0.03) |
| Distances (from Main Unit): | |
| --- Water Temp Sensor | 500' max (100' cable supplied) |
| --- Anemometer | 40' max (25' cable supplied) |
| --- Humidity and Air Temp Sensor | 25'max (15' cable supplied) |
| Wireless: (LOS = line of site) | |
| --- Transceivers | 900MHz, 115Kbps, 1000mW |
| --- Range - 8" Antennas | 3000' LOS, 1000' obstructed |
| --- Range - High Gain Yagi Antennas | 2 Miles LOS, 3500' obstructed |
| Main Unit Dimensions | 9.5" x 6.5" x 4.0" |
| Humidity/Air Temp Unit Dimensions | 4.0" x 2.0" x 1.5" |