SPECIFICATIONS
Operating Temperature Range | -40°F to +150°F |
Input Power Type | AC or DC |
Input Power if AC | 120VAC @ 5W |
Input Power if DC | 12VDC @ 200mA |
Maximum Wind Speed | 120MPH |
Humidity Range | 5-99% |
Temperature Range (air) | -40°F to 150°F |
Temperature Range (water) | Liquid to 120°F |
Accuracy calibrated (uncalibrated): | |
--- Temperature (°F) | +/- 1°F (+/- 2.5°F) |
--- Wind Speed (MPH) | +/- 2MPH (+/- 4MPH) |
--- Relative Humidity (%) | +/- 2% (+/3.5%) |
--- Barometric Pressure (InHg) | +/- 0.01 (0.03) |
Distances (from Main Unit): | |
--- Water Temp Sensor | 500' max (100' cable supplied) |
--- Anemometer | 40' max (25' cable supplied) |
--- Humidity and Air Temp Sensor | 25'max (15' cable supplied) |
Wireless: (LOS = line of site) | |
--- Transceivers | 900MHz, 115Kbps, 1000mW |
--- Range - 8" Antennas | 3000' LOS, 1000' obstructed |
--- Range - High Gain Yagi Antennas | 2 Miles LOS, 3500' obstructed |
Main Unit Dimensions | 9.5" x 6.5" x 4.0" |
Humidity/Air Temp Unit Dimensions | 4.0" x 2.0" x 1.5" |